Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA (AGA, CGA).
5.0 Amps
Each compartment has capacity for:
Three, 12˝ x 20˝ x 2
1
˝ or six, 12˝ x 20˝ x 1˝ deep
2
Cafeteria Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS
TOTAL ALKALINITY
SILICA
pH FACTOR
CHLORINE
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
The fact that a water supply is potable is not proof that it will
be suitable for the generator.
Right - 6", Left - 6", Rear - 6" (12"
on control side if adjoining wall
or equipment is over 30" high for
service acess)
1 1/2" NPT common drain.
For use in non-
Do not connect other units
combustible locations.
to this drain.
Contact factory for
Do not use PVC pipe for
variances to clearances.
drain.
less than 60 parts per million
less than 20 parts per million
less than 13 parts per million
greater than 7.5
less than 30 parts per million
(NOT TO SCALE)