Cleveland SteamCraft V Service Manual page 31

Counter type convection steamer
Table of Contents

Advertisement

Printed 4/90
3. Refer to figure 2-25 and press the TIME SET one minute touch pad (5) to
increase TIME DISPLAY from 00 to 09, then back to 00.
4. Refer to figure 2-25 and press the TIME SET ten minute touch pad (4) to
increase TIME DISPLAY from 00 to 90, then back to 00.
5. Set the TIME DISPLAY to 01 and press the TIMED touch pad (6).
6. As the cycle starts, the steam generator heaters turn on. The green fight to
the light of the TIME DISPLAY should not be on.
7. As the steam generator reaches temperature, the green light begins
flashing. One heater contactor will cycle on and off every five Seconds 8.
8. The TIME DISPLAY counts down to 00, an alarm beeps four times
and the TIME DISPLAY flashes 00.
9. The heaters, fan, and condenser valve turn off.
10. Press the TIMED touch pad (6) to stop displays.
11. Set TIME to any number over OO. Press the MANUAL touch pad (2).
12. TIME DISPLAY resets to 00. The heaters, fan and condenser valve turn
on.
13. Allow unit to run for at least one minute to see that TIME DISPLAY
counts up.
SEVERE BURNS may result to eyes, nose, mouth or skin exposed to hot
steam.
Avoid hot steam. When opening steamer door,allow steam to vent before
reaching into steamer compartment.
14. Open the steamer door.
15. Steam flow stops. The heaters, fan, and condenser valve turn off.
16. Press the POWER touch pad to turn the steamer off. The red light over touch
pad terns off.
17. End of test.
CET-16 Service Manual
WARNING
Page 27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Steamcraft v cet-16

Table of Contents