Water Quality Requirement - Cleveland Enodis 24-CDM Specification Sheet

Classic convection steamers 15 psi boiler base style cleveland classic series

Advertisement

NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, NSF and CSA.
1 1/2" IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
Each compartment has capacity for:
Three, 12˝ x 20˝ x 2
1
˝ or six, 12˝ x 20˝ x 1˝ deep
2
Cafeteria Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY
SILICA
pH FACTOR
CHLORINE
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be
necessary. The fact that a water supply is potable is not
proof that it will be suitable for the generator.
Right - 3", Left - 3", Rear - 3"
(12" on control side if adjoin-
ing wall or equipment is over
30" high for service acess)
Contact factory for
variances to clearances.
less than 20 parts per million
less than 13 parts per million
greater than 7.5
less than 30 parts per million
(NOT TO SCALE)
III
SECT.
PAGE
0707
Litho in U.S.A.
8