Page 10
CET-16 Service Manual

Water Supply Lines

Printed 4/90
4. Install a separate disconnect switch and fuses sized to line amps (see
Table 2 -3). The fuses may be an integral part of the disconnect switch
or in a separate fuse box.
5. There should be a sufficient length of flexible conduit between the
SteamCraft V connector and the wall so the unit can be moved for
service.
• Canadian steamers arc supplied with six feet of flexible conduit for
compliance with Canadian Standards Association. The electrical
supply line must end in a junction box behind the steamer for
connection of the flexible cable from the steamer.
6. Each steamer MUST be electrically grounded by the installer.
7. The characteristics of the electric power supply must match the power
requirements specified on toe SteamCraft V product identification
plate. The plate is located on the left side of the unit (refer to figure 1-
1).
8. All SteamCraft V's are wired for 3 phase only, and are not convertible
to single phase.
Furnishing and plumbing the water supply lines is the responsibility of the
owner and/or installer. Figures 2-2 and 2-3 illustrate plumbing layouts
recommended by Cleveland Range. When installing water supply fines,
observe the following instructions.
1. Always connect a COLD water supply to the condenser/steam gener-
ator connection (item 4, figure 2 -1). If hot or warm water is supplied to
this connection, the steam condenser in the SteamCraft V will not work
2. Supply water pressure must be a minimum dynamic pressure of 35 psi
2
(2.4 kg/cm
) and a maximum static pressure of 60 psi (4.1 kg/cm
3. The recommended size for the water supply lines is 1/4'L.P.S. This is
the size of toe lines in the SteamCraft V. If larger lines are used, a
pressure reducer must be installed in the supply line to maintain the
pressure specified in #2, above.
4. NSF requires the installation of a check-valve in accordance with and
as required by local plumbing codes.
5. When a water treatment system is not installed, Cleveland Range
recommends the plumbing layout illustrated in figure 2-2.
6. When a water treatment system is installed, Cleveland Range recom-
mends the plumbing layout illustrated in figure 2-3.
• The water supply to the condenser/steam generator connection (item
4, figure 2-1) can be untreated.
• The treated water supply is connected to the steam generator only
connection (item 5, figure 2-1).
• The steam generator only connection requires plumbing changes
inside the SteamCraft V. These changes can be made only by an
authorized service representative.