STEAM GENERATOR DESCALING PROCEDURE

3. Remove the filter screen and wash it with clean water.
figure 4-2.
4. Put screen back into cap and screw cap into strainer.
5. Open water valve and check for water leaks.
Steam generator should be descaled at least once a month, depending
on scale buildup. If you have serious steam generator scale buildup,
install a water treatment system for the steamer. Cleveland Range, Inc.
recommends use of the descaling kit (part number 101751). Full descal-
ing may take several hours, or more than one add process. Perform
descaling until an scale buildup is cleaned out.
Liquid Phosphoric Acid can be harmful if not
handled properly. Follow these basic safety
rules for handling and using acid.
• Wear protective clothing when mixing or apply-
ing chemical cleaners. Wear rubber gloves,
mask and approved cup-type goggles.
• Avoid breathing fumes and dust If dust or liquid
comes in contact with skin, flush immediately
with large quantities of cold water. Remove
contaminated clothing.
• If chemical contacts eyes, flush with cold water
for a minimum of 15 minutes. Get immediate
medical attention.
• If chemical is swallowed or ingested, follow
instructions on the chemical container. Get
immediate medical attention.
Do not scrape healing elements or water level
probes with a solid tool.
1. Make sure that electrical power is turned off at the disconnect switch
and that the steam generator drain valve is open. Allow time for the
steamer compartment and steam generator to cool down before
performing step 2.
CET-16 Service Manual