CONTROL PANEL WARNINGS

START-UP AND PREHEAT

Printed 4/90
If FLOOD light is flashing, DO NOT OPEN COM-
PARTMENT DOOR! Shut off water valve to steamer
and allow steamer to cool down before opening
steamer door.
FLOOD is a high water alarm. It lights when the water level in the
steam generator is too high. Steamer operation stops and cannot be
restarted until the cause of the FLOOD message is corrected. The
compartment must be drained completely, and the POWER touch pad
pressed twice to remove the FLOOD alarm. Refer to Troubleshooting in
Chapter 4.
WATER is a low water alarm. It lights when the water level in the
steam generator is too low. The heaters in the steam generator win not
mm on until the water level is high enough for safe steam generator
operation. When the steamer is first turned on, the WATER safely
warning normally displays until the steam generator fills to the proper
level.
If the FLOOD or WATER alarm does not turn off when the water level is
corrected:
1. Open the drain valve.
2. Wash out the steamer compartment and steam generator.
3. Descale the steam generator.
4. Refer to Troubleshooting in Chapter 4.
5. If the FLOOD or WATER alarm still does not function correctly,
arrange to have an Authorized Service Representative inspect and
repair the steamer.
1. Make sure that the drain valve is dosed and the compartment drain is
clear of debris. The fan guard, slide racks and steam generator
cover must be installed in the steamer compartment. Close the
steamer door.
2. Press the POWER touch pad. The red light above POWER and the
WATER alarm light turn on. Water starts to run until the steam
generator fills wish water. When the proper water level is reached,
the water and the WATER alarm light turn off. The heaters turn on
to heat the steam generator water to stand-by temperature.
3. Press the MANUAL touch pad. The green light above the touch pad
turns on. Wait about five minutes for steam to preheat the compart-
ment.