steamer shuts off and cannot be turned on until the
problem is corrected. Refer to Troubleshooting in
Chapter 4.
8. WATER WATER is a low water safety warning. It indicates
that the water level in the steam generator is too
low. Water cannot be heated until the steam
generator has enough water to operate, safely.
When the steamer is first turned on, the WATER
safety warning normally displays until the steam
generator fills to the proper level.
9. DIGITAL TIME DISPLAY
• The DIGITAL TIME DISPLAY shows cooking
time.
• When MANUAL cooking is selected, the TIME
DISPLAY counts up from 00 so the operator can
watch elapsed time until the proper cooking time
has been reached.
• When TIMED cooking is selected, the TIME
DISPLAY counts down from the time set using
the left and right TIME SET touch pads.
• A green light to the right of the TIME DISPLAY
flashes on and off when the dock is counting.
This green light turns off when the dock stops
counting.
• Counting stops when the steamer door is
opened or when the steamer compartment is not
up to temperature.