Cleveland SteamCraft V Service Manual page 9

Counter type convection steamer
Table of Contents

Advertisement

1. Electrical conduit access to terminal block inside
back cover.
• Canadian steamers are supplied with six feet of
flexible conduit for compliance with Canadian
Standards Association.
2. A separate disconnect switch with fuses sized to
line amps (see Table 2-3) MUST be installed for
each steamer.
• Furnished and installed by others.
3. The steamer MUST be electrically grounded by the
Installer.
Figure 2-1. Schematic Installation Diagram
4. Untreated cold water connection (1/4'' NPT).
• Steam Generator and Condenser supply for
• Condenser supply for units with SteamerGard
5. Access for treated cold water connection.
• Steam Generator supply for units with Steamer-
• Requires additional parts and installation by
6. Drain outlet connection with 1-1/4" NPT.
• Outlet extension connects to drain outlet.
• Outlet extension line has free air vented connec-
CET-16 Service Manual
units without water treatment system.
water treatment system.
Gard water treatment systems.
authorized service representative.
tion to floor drain.