Weekly Maintenance; Yearly Maintenance - Cleveland SteamCraft V Service Manual

Counter type convection steamer
Table of Contents

Advertisement

Page 48
CET-16 Service Manual

WEEKLY MAINTENANCE

YEARLY MAINTENANCE

The steamer is equipped with a drain screen in the back
of the cooking compartment. The steamer should never
be operated without the screen in place. This screen
prevents large food particles from entering and possibly
blocking the drain fine. Any blockage of the drain fine
may cause a slight buildup of back pressure in the
compartment resulting in steam leaks around the door
gasket. It also may adversely affect the convection
action of the steam in the compartment, which is neces-
sary for optimum performance.
1. Make sure the drain screen and drain line are not blocked. Pour USDA
approved drain cleaner through drain once a week.
2. Inspect for steam generator scale weekly. The frequency of steam
generator descaling depends upon water quality and daily steam
generator drain and washout. If steam generator scale buildup is a
frequent problem, install a water treatment system for the steamer. See
Water Quality Requirements on page 6.
3. Regardless of use, steam generator should be descaled at least once a
month. See Steam Generator Descaling Procedure below.
Clean the water line filter at least once a year as follows:
1. Close the valve in the steamer water line. Refer to figure 4-1.
2. Unscrew the filter from the bottom of the strainer which is located in
back of the steamer. Refer to figure 4-2.
WARNING