PROBLEM
POWER touch pad on, but panel
light does not turn on.
WATER alarm light on. Steamer
does not make any steam.
FLOOD alarm light on. (Steamer
controls do not work.)
Steam coming from drain hub.
Steam and/or water draining around
cabinet door.
Steam flow does not stop when timer
reads 00, or fan and heaters stay on
when cabinet door is open.
Printed 4/90
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
Electricity turned off.
Normally on during
FILLING
Water supply to steam generator
is turned off.
Water line filter is dogged.
Drain valve is open.
Inoperative controls.
WARNING: Do NOT open door.
Steamer flooded; drain closed
Drain clogged inside
steamer
False alarm by water splashing
on flood probe. Water pressure
too high.
Unit may need new flood probe
retrofit kit.
Water solenoid or controls
inoperative.
Water supply to condenser
turned off
Water line strainer is clogged
e
Water supply lin
to the can-
denser blocked, broken, or
leaking.
Inoperative condenser solenoid.
Inoperative controls.
Drain clogged or covered.
Door seal or door parts worn.
Steamer not level.
Inoperative controls inside
cabinet.
CET-16 Service Manual
REMEDY/REFERENCE
Turn on on electricity.
.
Open water supply valve.
n
Clea
out water supply filter-
Close drain valve.
See note #1.
Open drain.
.
See note #2.
Restart per note #3.
Contact service representative.
Turn electricity and water off and
refer to note #1.
Open water supply valve.
.
n
Clea
oat water supply strainer.
Repair or replace water supply line
See note #1.
Replace solenoid. See note #1.
Turn off electricity. See note #1.
n
Clea
drain with USDA approved
drain cleaner.
See note #1.
See note #6.
Turn off electricity. See note #1.
Page 51