Canadian Wiring Considerations; Connect Untreated Water Line - Cleveland SteamCraft V Service Manual

Counter type convection steamer
Table of Contents

Advertisement

Page 18
CET-16 Service Manual

Connect Untreated Water Line

Printed 4/90

Canadian Wiring Considerations.

For all applications in Canada, install the electrical power lines in accord-
ance with local codes and/or the Canadian Electrical Code, CSA Standard
C22-1 (Canada).
• Canadian steamers are supplied with six feet of flexible conduit
connected to the steamer and wired to the terminal block at the factory.
• The electrical supply line ends in a Junction box behind the steamer far
connection of the SteamCraft V flexible cable.
• Connect the wires from SteamCraft V flexible cable to those in the
Junction box according to figure 2-17.
• Each steamer MUST be electrically grounded by the installer.
Referring to Water Supply Lines (page 10) and figure 2-2, verify that the
water supply line has been extended to the SteamCraft V properly.
Connect the supply line to the SteamCraft V as described below.
1. If the untreated water supply fines are larger than 1/4" L.P.S., verify that
a pressure reducer has been installed to maintain the SteamCraft V
water pressure requirements specified in Water Supply Lines (page 10).
2. If the water strainer is not already connected to the SteamCraft V, refer to
Install The Water Strainer (page 15), and connect the water strainer to the
untreated water intake bulkhead coupling.
3. Remove the SteamCraft V rear panel by removing six screws (figure 2-
15) that hold it in place. Save the screws.
4. Verify that the cold water steam generator feed line and cold water
condenser feed lines are properly connected for the water supply
arrangement being used.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Steamcraft v cet-16

Table of Contents