Water Supply Requirements And Installation; Water Supply Requirements - Cleveland 24CGA10.2 Installation And Maintenance Instructions Manual

Dual gas steam generator & convection steamer
Hide thumbs Also See for 24CGA10.2:
Table of Contents

Advertisement

c. A main disconnect switch and a separate fuse or breaker should be installed near the unit as shown
in Figure 2-6. See Figure 2-1 or 2-2 for the steamers power requirements. Throughout the
remainder of this manual the fused disconnect switch is referred to as the main external power
switch.
d. Refer to the connection diagrams in Figure 2-7, and connect the wires to the terminal block and
ground connector accordingly.
DRAIN LINE
COLD WATER SUPPLY LINES
Figure 2-6, Recommended Electrical Layout

6. Water Supply Requirements and Installation

a. Water Supply Requirements
1). Water Quality
As with any steam generating equipment, poor water quality degrades the performance of the
steamer.
Check the quality of supply water as described below before starting construction of the water
supply lines. If a water treatment system must be installed to achieve acceptable water quality,
install it before connecting the water supply lines to the Gemini Steamer.
If softened or chlorinated water is used in a Gemini steam generator, a carbon type filter must
be used for the water before it enters the steamer to remove Chlorine or other salts. If the water
supply is treated or softened either by the Water Company or on the premises, it may contain
chlorine or various salts. These additives are damaging to the steam generator. Salts and
chlorine used to soften or treat water cause rapid scale buildup, and/or increased corrosion if
allowed to flow into the steamer.
Contact a local water treatment specialist for an on-the-premises water analysis. The
recommended minimum feed water quality requirements for the steamer are listed in Table 2-1.
MAIN EXTERNAL
POWER SWITCH
Gemini
Using water not within the limits specified in this
manual could void or reduce Cleveland Range's
warranty coverage of the steamer.
ELECTRICAL CONDUIT
INLET
TERMINAL
BLOCK
Figure 2-7, Electrical Connections
CAUTION
12
GROUND
LUG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gemini 24cga6.2Gemini 24cga10.2