Page 52
CET-16 Service Manual
PROBLEM
Water leaking from bottom of
cabinet.
Water leaking from water pipes or
Food takes too long to cook.
Cabinet bottom dirty with food drippings. Juices and/or food leaking from

TROUBLESHOOTING NOTES

Printed 4/90
TROUBLESHOOTING GUIDE (continued)
POSSIBLE CAUSE
Broken or loose parts inside
steamer cabinet.
Plumbing needs repair.
Trays too dose to the bottom of cabinet. Put trays in slots near top of cabinet.
Steam generator scale buil-
dup.,
Condenser on an the time
Cabinet overloaded with too much food. Put less food int
Voltage too low for unit
Suggested cooking times are for sea
level cooking.
perforated trays.
Do not attempt to open compartment door while steamer is
hot.
Some unit problems such as steam generator flooding or
no water in steam generator can be caused by dirt or
scale on water level probes inside steam generator. Try
descaling steam generator.
1. If problem is inside the steamer compartments, can an authorized
service representative. Cleveland Range, Inc. will not pay for warranty
repairs by unauthorized repair centers.
2. Perform the following procedure.
a. Turn water off at water supply valve.
b. Let steamer cool down for half an hour.
c. Place a container under steamer door to catch any water as door is
opened.
d. Clear drain of debris.
REMEDY/REFERENCE
Turn off electricity and dose water supply
valve(s). See note #1.
See note #5.
Descale
approved descaler.
.
See note #1
in cabinet.
See note #4.
Extend cooking times for altitudes above 2500
feet.
Put a solid tray under perforated trays to catch
drippings.
WARNING
NOTE
steam
generator
with
.
o
trays, or fewer trays
USDA