• If the water supply arrangement does not include a water treatment
system; refer to figure 2-18, and verify that the cold water steam
generator feed and condenser feed lines are attached to the tee and
bulkhead coupling inside the steamer.
• If the water supply arrangement includes a water treatment system;
refer to figure 2-19, and verify that the cold water condenser feed line
is attached to the tee and bulkhead coupling inside the steamer.
Verify that the steam generator supply outlet of the tee has been
securely capped.
5. Flush the water supply line before connecting it to the strainer intake
port
6. Apply pipe dope or teflon tape to the threads of the water supply line,
and securely connect the supply line to the strainer input port.
7. Turn on the untreated water supply, and check the lines for signs of
leakage, both outside and inside the steamer.
8. If no further work is required inside the SteamCraft V, secure the rear
panel in place using six mounting screws (figure 2-l5).