Free Air Vented Drain Lines

The drain outlet discharges exhaust steam and hot condensate from the
steamer. This discharge is usually under pressure. The drain outlet
MUST be free air vented to disburse the pressure, and avoid creating a
back pressure or a vacuum within the SteamCraft V.
• Backpressure will cause steam and hot water leakage around the door.
• A vacuum will implode the steamer.
Furnishing and plumbing the drain lines is the responsibility of the owner
and/or installer. Figure 2-7 illustrates a drain layout recommended by
Cleveland Range. Observe the following instructions to determine the
pipe size, the number of fittings required, and the layout of the drain line
path.
CET-16 Service Manual
Printed 4/90
Page 11