Door Switch Test

TIME and Temperature Tests

Printed 4/90
a. Aline the positioning stud as shown in figure 2-23.
b. Make sure fee wires are dear and secure the panel in place
with the mounting screws.
12. Close the steamer door. When the water level reaches the water
level probe (lowest), the WATER alarm turns off and the heater
contactors operate. The heating elements in the steam generator
start heating water.
1. Open the steamer door. Toe contactors, heaters and fan turn off.
2. Close the compartment door. Press the MANUAL touch pad. The
condenser valve, heater contactors, and fan motor turn on.
3. Check for condenser water flow from the drain.
4. Open the steamer door. The condenser valve, three heaters, one
contactor, and fan motor turn off.
5. Set a magnet over the door switch as shown in figure 2-23. The
condenser, fan and heaters turn on.
6. Remove the steam generator cover and check that all four
heating elements are on.
7. Remove magnet from the control panel.
Differences in heater outputs are observed during this procedure. To
emphasize these differences, start this procedure with cold water in
the steam generator. It may be necessary to drain and refill the
steam generator.
1. Install the steam generator cover in steam generator opening and
dose the steamer door.
2. Press the TIMED touch pad (6, figure 2-25).