Program 6: Toll Restriction
Filling Out the Program Record Form
Example
For Toll Level 02, International Dialing is not allowed, but all other calls that begin
with zero (0) are allowed (only this option will be shown).
Toll
Level
0 2
Entering Data Into Memory
To enter Program 6 data:
220
Y N
Enter program mode.
1.
-Press # + dial SP + dial 5312 + press #.
Press key 6 to enter Program 6.
2.
For first-time programming or to initialize (reset) all
3.
toll restriction levels: Dial I to initialize, then dial Y.
Otherwise, go to step 4.
-If you change your mind after dialing I, dial N. You
return to the TOLL PROG/INIT? prompt (i.e., the
beginning of step 3).
Dial P to program (change) the toll restriction values.
4.
-If you hear re-order tone and leave the program
mode, this means you must go to step 1 and
initialize in step 3.
Dial toll restriction level, press #.
5.
To accept the displayed data: Press #.
6.
OR
To change or enter data: Dial data, press #.
-To erase data before pressing #: Dial *.
-You do not need to press # after dialing "A" or "D".
-When you see, "ADD-DELETE-LIST", you can
add, delete or list codes in the Allow/Deny Tables
(go to the proper Tables on the next two pages).
Repeat steps 6 until you enter all data for a toll level.
7.
-If you finish and do not see, "TOLL LEVEL": Press
# until you do see it.
DIGITAL SYSTEM Administrator's Guide
System Options
0 1 8 5 3 I 2 ( D )