Printronix PrintNet P8000 Line User Manual page 180

Line matrix printers printnet ethernet
Table of Contents

Advertisement

Chapter 12
Complete Command List
Example: store pserver opts jobtimeout 5
The jobtimeout applies to the active job only and starts
counting from zero each time data has been handed over to the
printer successfully. If a blocked condition occurs for instance
no data can be written the the printer, the print job will be
cancelled after the timeout. The default for jobtimeout is 0
which is disable.
The multcp option determines how many concurrent socket
connections are allowed.
Example: store pserver opts -multcp
When multcp is disabled, only a single socket connection is
allowed at a time.
Example: store pserver opts multcp
With this option, multiple concurrent socket connections are
allowed. The default multcp is set to be enabled.
store pserver tcpsocket <TCP-PORT> port <NEW-TCP-PORT>
Example: store pserver tcpsocket 4000 port 5000
Change a pre-defined TCP port number (<tcp-port>) on the
PrintNet to a new TCP port number (<new-tcp-port>). The
default number is 9100 for prn.
store pserver tcpsocket <TCP-PORT> dest <DEST>
Example: store pserver tcpsocket 5000 dest d1prn
Assign a pre-defined TCP port number (<tcp-port>) to a
particular destination (<dest>) on the PrintNet. Therefore, if you
are using a print method that sends jobs directly to a TCP port
number, you still have the option to process the job data
through this destination setting.
store pserver tcpsocket add <TCP-PORT> dest <DEST>
Example: store pserver tcpsocket add 9101 dest d2prn
Maps the port number to a destination.
store pserver tcpsocket del <TCP-PORT> dest <DEST>
Example: store pserver tcpsocket del 9101 dest d2prn
Deletes a mapped port number destination already defined by
listed commands.
180