Installing A Ddr-2 Dimm Memory Module - Sun Microsystems Netra CP3060 User Manual

Blade server
Table of Contents

Advertisement

2.4.1.1

Installing a DDR-2 DIMM Memory Module

The following procedure provides a general guide for installing additional memory.
However, for directions on the installation process of the memory DDR-2 DIMMs on
the Sun Netra CP3060 blade server, refer to the documentation that shipped with the
memory module.
Caution – Do not remove the DDR-2 DIMM from its antistatic container until you
are ready to install it on the card. Handle the module only by its edges. Do not touch
module components or metal parts. Always wear a grounded antistatic wrist strap
when handling modules.
1. Locate the DDR-2 DIMM connectors on the Sun Netra CP3060 blade server.
Select the connectors where you will install the memory module (see
If you need to replace an existing memory module with a new module, see
Section 2.4.1.2, "Removing a DDR-2 DIMM Memory Module" on page 2-8
instructions on removing the DDR-2 DIMM module.
2. Remove the DDR-2 DIMM from its protective packaging, holding the module
only by the edges.
3. Insert the bottom edge of the DDR-2 DIMM into the bottom of the slot's
hinge-style connector (see
The socket and module are both keyed, which means the module can be installed
one way only. With even pressure, push simultaneously on both upper corners of
the DDR-2 DIMM until its bottom edge (the edge with the gold fingers) is firmly
seated in the connector.
).
FIGURE 2-2
Chapter 2
FIGURE 2-1
for
Hardware Installation
).
2-7