Netra Proxy Cache 1.0 Server to Array Upgrade Instructions A Sun Microsystems, Inc. Business 901 San Antonio Road Palo Alto, , CA 94303-4900 Part No: 805-3511-10 Revision A, March 1998...
Page 3
Netra Proxy Cache 1.0 Server to Array Upgrade Instructions Part No: 805-3511-10 Revision A, March 1998...
Page 4
52.227-14(g)(2)(6/87) and FAR 52.227-19(6/87), or DFAR 252.227-7015(b)(6/95) and DFAR 227.7202-3(a). Sun, Sun Microsystems, the Sun logo, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc.
Contents Netra Proxy Cache Server to Array Upgrade Instructions 1 Upgrade Kit Components 2 Upgrade Procedure Overview 2 Installing the FastEthernet Card 2 To Install the FastEthernet Card 4 Upgrading to Array Software 8 To Upgrade the Netra Proxy Cache Software 9 System Recovery 10 To Restore the Solaris Operating Environment and Netra Proxy Cache Packages 11...
Page 6
Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998...
CHAPTER Netra Proxy Cache Server to Array Upgrade Instructions “Upgrade Kit Components” on page 2 “Upgrade Procedure Overview” on page 2 “Installing the FastEthernet Card” on page 2 “Upgrading to Array Software” on page 8 “System Recovery” on page 10 This document explains how to upgrade your Netra Proxy Cache Server to the Netra Proxy Cache Array product.
Server product. The numbered panels in Figure 1–1 and Figure 1–2, below, illustrate the steps involved in installing the FastEthernet card. Detailed written instructions follow the figures. Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998...
Page 9
Figure 1–1 Powering Off, Attaching Wrist Strap, Removing Filler Panel Netra Proxy Cache Server to Array Upgrade Instructions...
1. In the Netra Main Administration page, click Restart and Shutdown. 2. In the Restart and Shutdown Administration page, click Shutdown. Make sure “Check for new devices during restart” is selected. Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998...
Page 11
3. When the shutdown completes (after about 60 seconds), press the Standby ( 4. )side of the power switch. See panel 1 of Figure 1–3. 5. Grasp the side panel and pull it toward the back of the system. Lift up and remove the panel.
Page 12
Examples that follow in this document and in the Netra Proxy Cache Array manuals assume that the second network interface is installed in slot 2 (J1401). Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998...
Page 13
Figure 1–4 PCI Card Slots 9. Fit the card back panel into one of the system chassis card slots, and lower the card connector so that it touches its associated card slot on the main logic board. 10. Push the card by its corners straight down into the slot until the card is fully seated.
The references for this procedure are the Netra Proxy Cache Array Configuration Guide and User’s Manual. The following procedure requires that you have a serial terminal connected to your Netra Proxy Cache Server. Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998...
If you want, you can back up your Netra Proxy Cache Server configuration before starting the following procedure. This backup procedure is described in Chapter 3 of the Netra Proxy Cache Server Configuration Guide. To Upgrade the Netra Proxy Cache Software 1.
Netra Proxy Cache Array host. The recovery procedure for a Netra Proxy Cache Array host is described in Appendix A of the Netra Proxy Cache Array Configuration Guide. Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998...
6. At the ok prompt, enter: ok boot cdrom The Solaris boot process starts. The following prompt is displayed: Please confirm that you want to reinstall Netra Proxy Cache 1.0. This will ERASE ALL EXISTING DATA on the system. Answer yes, no or quit: y 7.
In the Install Configuration page, select the host you are restoring and click Install Selected Hosts. See the Netra Proxy Cache Array Configuration Guide for details on the Install Configuration feature. Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998...
Need help?
Do you have a question about the Netra Proxy Cache 1.0 and is the answer not in the manual?