110 en | Appendix
Contact
IN4
GND
R
Connect each alarm input to a ground contact (GND) when connecting alarm inputs.
8.9

Communication with terminal program

Data terminal
If a VideoJet XF E cannot be found in the network or the connection to the network is
interrupted, you can connect a data terminal to the VideoJet XF E for initial setup and setting
of important parameters. The data terminal consists of a computer with a terminal program.
You require a serial transmission cable with a 9-pin Sub-D plug to connect to the computer
and open ends for connection to the terminal block of the VideoJet XF E.
Further topics:
HyperTerminal, a communications accessory included with Microsoft Windows, can be used
as the terminal program.
NOTICE!
Information on installing and using HyperTerminal can be found in the manuals or in the online
help for Microsoft Windows.
1.
2.
Configuring the terminal
Before the terminal program can communicate with the VideoJet XF E, the transmission
parameters must be matched. Make the following settings for the terminal program:
Command inputs
After the connection has been established, you must log on to the VideoJet XF E to access the
main menu. Other submenus and functions can be accessed using the on-screen commands.
1.
2.
3.
Assigning an IP address
Before you can operate a VideoJet XF E in your network you must first assign it an IP address
that is valid for your network.
DOC | V5.51 | 2012.03
Function
Input alarm 4
Ground
Relay output
Section Pin assignment serial interface, page 109
Disconnect the VideoJet XF E from the Ethernet network before working with the
terminal program.
Connect the serial interface of the VideoJet XF E using any available serial interface on
the computer.
19,200 bps
8 data bits
No parity check
1 stop bit
No protocol
If necessary, turn off the local echo so that entered values are not repeated on the
display.
Enter one command at a time.
When you have entered a value, such as the IP address, check the characters you have
entered before pressing Enter to transfer the values to the VideoJet XF E.