Installing in a Switch Cabinet 4.3.1 Preparations 4.3.2 Installing the VideoJet XF E Connections Power on/Power off Setup using Bosch Video Client Configuration using a Web browser Connecting Configuration menu Basic Mode: Device Access Basic Mode: Date/Time Basic Mode: Network...
Page 4
Recording video sequences Running recording program The RECORDINGS page Hardware connections between video servers Operation using software decoders Maintenance and upgrades Testing the network connection Unit reset Repairs DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 5
Malfunctions with iSCSI connections LEDs Processor load Network connection Serial interface Terminal block Communication with terminal program 8.10 Copyrights Specifications VideoJet XF E Power supply unit delivered Glossary Index Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Various functions can be triggered automatically by incorporating external alarm sensors. Other applications are not permitted. In the event of questions concerning the use of the unit which are not answered in this manual, please contact your sales partner or: Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com...
– If safe operation of the unit cannot be ensured, remove it from service and secure it to prevent unauthorized operation. In such cases, have the unit checked by Bosch Security Systems. Safe operation is no longer possible in the following cases: –...
Never open the housing of the power supply unit. The power supply unit does not contain any user-serviceable parts. – Ensure that all maintenance or repair work is carried out only by qualified personnel (electrical engineers or network technology specialists). DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
– Microsoft Internet Explorer (version 7.0 or higher) – Receiver software, for example Bosch Video Client (version 1.3 or higher) or Bosch Video Management System (version 3.0 or higher) – H.264 compatible hardware decoder from Bosch Security Systems (for example VIP XD HD) as a receiver and connected video monitor –...
Viewing View the VideoJet X20/X40 XF E encoder video on a PC using a Web browser, in the Bosch Video Management System, or integrate it into another video management system. By routing the IP video to a high-performance VIP XD HD video decoder you can present the video with ultimate clarity.
Page 11
ONVIF conformant devices are able to exchange live video, audio, metadata and control information and ensure that they are automatically discovered and connected to network applications such as video management systems. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 12
Flexible encryption of control and data channels – Authentication according to international standard 802.1x – Bidirectional audio (mono) for line connections – Audio encoding to international standards AAC, G.711, and L16 DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
12V DC power connector for connecting the power supply unit Further topics: – Section 8.4 LEDs, page 108 – Section 8.8 Terminal block, page 109 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 14
12V DC power connector for connecting the power supply unit Further topics: – Section 8.4 LEDs, page 108 – Section 8.8 Terminal block, page 109 DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
– Avoid impacts, blows and severe vibrations that exceed the specification limits, as these can irreparably damage the unit. Further topics: – Section 9 Specifications, page 113 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Slide the unit into the plastic frame until you feel it lock securely into place. – Finally, check that the unit is securely attached in the installation location. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
The VideoJet XF E can be installed in a 19-inch rack. A Rack Mount Kit for the installation of up to 3 VideoJet XF E can be obtained from Bosch. For more information access your Bosch product catalog on the Internet.
Page 18
IN 2 IN 3 IN 4 AU DIO AU DIO OU T IN 1 IN 2 IN 3 IN 4 AU DI O IN AU DI O OU DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
NOTICE! The release letter for the current firmware version includes a list of compatible CF cards. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 20
The relay output is also located on the orange terminal block. CAUTION! A maximum load of 30 V (SELV) and 200 mA may be applied to the relay contact. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Setup using Bosch Video Client For the current version of the Bosch Video Client (BVC) management software, access your Bosch product catalog on the Internet. This program allows you to implement and set up the encoder in the network quickly and conveniently.
Page 22
Follow the instructions given in the Configuration Wizard window. Additional parameters You can check and set additional parameters with the assistance of the Configuration Manager application in Bosch Video Client. You can find detailed information on this in the documentation for these applications. DOC | V5.51 | 2012.03...
NOTICE! Also note the information in the Releaseletter document for the respective firmware. For the latest version of the firmware, required programs and controls, access your Bosch product catalog on the Internet. The Web browser must be configured to enable cookies to be set from the IP address of the unit.
Page 24
If you do not connect, the unit may have reached its maximum number of connections. Depending on the unit and network configuration, each VideoJet XF E can have up to 25 Web browser connections or up to 50 connections via Bosch Video Client or Bosch Video Management System.
Section 5.12 Advanced Mode: Date/Time, page 35 Starting configuration Click the SETTINGS link in the upper section of the window. The Web browser opens a new page with the configuration menu. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 26
CAUTION! Save each change with the associated Set button. Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
It will be displayed in the video screen if configured to do so. The camera name makes the task of administering cameras in larger video monitoring systems easier, for example using the Bosch Video Client or Bosch Video Management System programs. Enter unique, unambiguous names for each camera in these fields.
The unit polls the time signal automatically once every minute. Enter the IP address of a time server here. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
IP addresses automatically assigned to the VideoJet XF E. Certain applications (Bosch Video Client, Bosch Video Management System) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server...
You can record the images from the camera connected to the VideoJet XF E on the local CompactFlash card. CompactFlash cards are the ideal solution for shorter storage times. Here you can start or stop the recording. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail. 5.10 Advanced Mode: Identification DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 33
Bosch Video Client or Bosch Video Management System programs. Enter unique, unambiguous names for each camera in these fields. You can use both lines for this.
Do not use any special characters, for example &, in the password. Special characters are not supported by the system's internal management. Confirm password In each case, enter the new password a second time to eliminate typing mistakes. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Clicking the Delete button will remove the entry from the table. Select other values from the list fields below the table to change the entry. Changes are made immediately. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)). In the Position (XY) fields, enter the values for the desired position. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
If you want to use the original graphics again, simply delete the entries in the Company logo and Device logo fields. Website language Select the language for the user interface here. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
There are always two languages to choose from: English and another language. If the language you require is not available for selection, you can download the current firmware with another language combination from the Bosch product catalog on the Internet. Company logo Enter the path to a suitable graphic if you want to replace the manufacturer's logo.
Page 39
Enter the path for the storage location of individual images and video sequences that you can save from the LIVEPAGE. If necessary, click Browse to find a suitable directory. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Reboot device Click Reboot to restart the VideoJet XF E. Factory defaults Click Defaults to restore the factory defaults for the VideoJet XF E. A confirmation screen appears. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
The numbering follows the labeling of the video inputs on the VideoJet XF E. 75 Ohm termination Select Off if the video signal is to be looped through. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
The check mark is hidden and the zone is only displayed as a faint mark in the preview. Click the zone with the right mouse button and then click Remove to delete the zone. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
You can use this function to adjust color saturation in order to correct unnatural camera signal colors. Brightness (0...255) You can use this function to adapt the brightness of the video image to your working environment. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
– High resolution 1 High quality for connections with the highest bandwidth, resolution 704 × 576/480 pixels DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 45
Change the profiles only once you are fully familiar with all the configuration options. In the default setting, Stream 2 is transmitted for alarm connections and automatic connections. Bear this fact in mind when assigning the profile. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 46
I-frame. Note that the values supported depend on the GOP structure setting. For example, only even values are supported with IBP; if you have selected IBBP, only 3 or multiples of 3 are supported. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 47
(IP frames only) or using as little bandwidth as possible. Default Click Default to return the profile to the factory default values. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Select a format for audio recording. The default value is AAC. If your system does not support AAC, select G.711 or L16 depending on the required audio quality or sampling rate. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Click Update to have the camera image automatically updated at regular intervals. Check the other cameras in the same way. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
It is also possible to let the VRM Video Recording Manager control all recordings when accessing an iSCSI system. This is an external program for configuring recording tasks for video servers. For further information please contact your local customer service at Bosch Security Systems.
Page 51
You can specify limitations for overwriting old recordings by configuring the retention time. Further topics: – Section 5.27 Advanced Mode: Retention Time, page 56 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
A small arrow is then displayed next to the IP Address field. Click the arrow to display the list of devices detected. Click the required device in the list to transfer its IP address. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
You can select multiple camera inputs by holding down the shift or [Ctrl] key as usual in Windows. The following settings apply to all selected entries. If necessary, click the Default button to return all settings to their default values. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 54
The analysis alarm is configured and activated on the VCA page. The audio alarm is configured and activated on the Audio Alarm page. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 55
NOTICE! For more information, please see the Alarm Task Script Language document and the RCP+ documentation. For the latest version of these documents access your Bosch product catalog on the Internet. Recording includes You can specify whether, in addition to video data, audio data and metadata (for example alarms, VCA data and serial data) should also be recorded.
Retention time Enter the required retention time in hours or days for each recording. Recording 1 corresponds to Stream 1, Recording 2 corresponds to Stream 2. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
This allows you to apply a schedule for Sundays to other days with dates that fall on varying weekdays. Click the Holidays tab. Any days that have already been selected will be shown in the table. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 58
Click Stop to deactivate the recording scheduler. Running recordings are interrupted. Recording status The graphic indicates the recording activity of the VideoJet XF E. You will see an animated graphic while recording is taking place. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Configuration using a Web browser | en 5.29 Advanced Mode: Recording Status Certain details on the recording status are displayed here for information purposes. You cannot change any of these settings. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Destination IP address For each number, enter the corresponding IP address for the desired remote station. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 61
Bosch Video Client or Bosch Video Management System, you can store a general password here. The VideoJet XF E can use this general password to connect to all remote stations protected with the same password.
Page 62
The numbering follows the labeling of the video inputs on the device. Depending on the system configuration, the receiver can then select the other cameras as well. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Select a VCA configuration and make the required settings. If necessary, click the Default button to return all settings to their default values. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
VCA configuration Select one of the profiles here to activate it or edit it. You can rename the profile. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 65
– The individual parameters must be configured to suit the operating environment and the desired responses. – The sensitivity must be set to a value greater than zero. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 66
Right-click any fields you wish to deactivate. Click OK to save the configuration. Click the close button X in the window title bar to close the window without saving the changes. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Click the Select All button to link all time intervals to the selected profile. Click the Clear All button to deselect all of the intervals. When you are finished, click the Set button to save the settings in the unit. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 68
Click the date you wish to delete. Click OK. The item will be deleted from the table and the window will close. The process must be repeated for deleting additional days. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
If the original condition has been restored before this time interval elapses, the alarm is not triggered. A delay period may be useful in avoiding false Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the Bosch Video Client and Bosch Video Management System programs. You can also use the name in the Forensic Search program function as a filter option for quick search in recordings.
Otherwise leave the box blank (0.0.0.0). SMTP user name Enter a registered user name for the chosen mailserver here. SMTP password Enter the required password for the registered user name here. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 72
Test e-mail You can test the e-mail function by clicking the Send Now button. An alarm e-mail is immediately created and sent. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Alarm Task Script Language document. For the latest version of this document access your Bosch product catalog on the Internet. As an alternative to the alarm settings on the various alarm pages, you can enter your desired alarm functions in script form here.
In monostable mode, you can set the time after which the relay will return to the idle state. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 75
Special characters are not supported by the system's internal management. Trigger relay Click the button to trigger the relay manually (for testing or to operate a door opener, for example). Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Stop bits Select the number of stop bits per character. Parity check Select the type of parity check. Interface mode Select the desired protocol for the serial interface. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
VideoJet XF E Configuration using a Web browser | en 5.41 Advanced Mode: Network Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 78
IP addresses automatically assigned to the VideoJet XF E. Certain applications (Bosch Video Client, Bosch Video Management System) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server...
Page 79
DynDNS.org and you must have registered the required host name for the unit on that site. NOTICE! Information about the service, registration process and available host names can be found at DynDNS.org. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 80
To transfer the IP address of the VideoJet XF E, click the Register button. Status The status of the DynDNS function is displayed here for information purposes. You cannot change any of these settings. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot. Make the desired changes. Click the Set and Reboot button. The VideoJet XF E is rebooted and the changed settings are activated. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 82
SSDP Discovery Service must be active in Windows XP and Windows 7. This function should not be used in large installations because of the variety of potential registration notifications. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
A special IP address (class D address) must be configured for multicast operation in a multicast-enabled network. The network must support group IP addresses and the Internet Group Management Protocol (IGMP V2). The address range is from 225.0.0.0 to 239.255.255.255. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 84
You can enter a value to specify how long the multicast data packets are active on the network. This value must be greater than one if multicast is to be run via a router. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
A number from 000 to 255 is added to the file name and automatically incremented by 1. When it reaches 255 it starts again from 000. – Date/time suffix The date and time are automatically added to the file name. When setting this parameter, Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
For example: With IP address 192.168.0.0 and corresponding mask 255.255.255.128 only IP addresses in the range from 192.168.0.0 to 192.168.0.127 are allowed to actively connect to the camera/encoder. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
First store the firmware file on your hard drive. Enter the full path of the firmware file in the field or click Browse to locate and select the file. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 88
You can download an internal maintenance log from the unit to send it to Customer Service for support purposes. When doing this, ensure that HTTPS browser port is not set to Off and DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
You can enter the activation key to release additional functions or software modules. NOTICE! The activation key cannot be deactivated again and is not transferable to other units. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
– Does the VideoJet XF E respond to alarm events as required? – Do the recordings occur as intended? – Is it possible to control peripherals if necessary? DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
NOTICE! Also note the information in the Releaseletter document for the respective firmware. For the latest version of the firmware, required programs and controls, access your Bosch product catalog on the Internet. The Web browser must be configured to enable Cookies to be set from the IP address of the unit.
If you do not connect, the unit may have reached its maximum number of connections. Depending on the unit and network configuration, each VideoJet XF E can have up to 25 Web browser connections or up to 50 connections via Bosch Video Client or Bosch Video Management System.
Page 93
Control options for peripherals (for example a pan/tilt head or dome camera) depend on the type of unit installed and on the configuration of the VideoJet XF E. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 94
To display a pre-set view, click one of the buttons numbered one to six. View Control ROI With the Stream 2 tab a specific type of View Control panel is activated for electronic pan/ tilt/zoom functions. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 95
To activate this, click the icon for the relay next to the video image. The icon will be red when the relay is activated. System Log / Event Log Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Quad View view (VideoJet X40 XF E). The icons below the camera images apply to the camera images in the following sequence: top left, top right, bottom left, bottom right. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
You can ascertain from the Dual View view (VideoJet X20 XF E) or the Quad View view (VideoJet X40 XF E) for which camera a recording is running by moving the cursor over the icon. A message is displayed below the cursor. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
From the Video list select the video input from which you want to view the recordings. Select 1 or 2 from the Recording list. The contents for 1 and 2 are identical, only the quality and location may be different. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 99
When you use the electronic pan/tilt on the full image you also zoom into the region of interest automatically. To zoom in on a region of interest: Zoom in Zoom out Reset to full image Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 100
In addition, you can set markers in the sequences, so-called bookmarks, and leap directly to these. These bookmarks are indicated as small yellow arrows above the time interval. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
NOTICE! Connecting with a Web browser is described in the manual of the relevant unit that is to be used as the receiver, for example VIP XD HD. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Bosch CCTV products as one component of an extensive video security management system. It allows you to integrate your existing components into a simple-to-control system or into the entire Bosch range, benefiting from a complete security solution based on the latest technology and years of experience.
Page 103
VideoJet XF E Operation | en 103 and, on release of the MOTION+ motion detector, record the activated cells to enable intelligent motion search. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Section 5.47 Advanced Mode: Maintenance, page 87 – Section 3.4 Connections, controls and displays, page 13 – Section 4.6 Setup using Bosch Video Client, page 21 Repairs CAUTION! Never open the housing of the VideoJet XF E. The unit does not contain any user-serviceable parts.
The VideoJet XF E should only be passed on together with this installation and operating manual. Your Bosch product is designed and manufactured with high-quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
If you are unable to resolve a malfunction, please contact your supplier or systems integrator, or go directly to Bosch Security Systems Customer Service. You can view a range of information about your unit version on the System Overview page.
Page 107
/main.htm in your Web browser and repeat the upload. Placeholder with a red JVM not installed on your Install Sun JVM from the Bosch cross instead of the computer or not activated. product catalog on the Internet. ActiveX components.
You can obtain additional information to help you when troubleshooting or fine tuning the unit. The values indicate the proportions of the individual functions on the encoder load, shown as percentages. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Assigning an IP address Before you can operate a VideoJet XF E in your network you must first assign it an IP address that is valid for your network. DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 112
Software This software is based in part on the work of the Independent JPEG Group. Audio AAC audio technology licensed by Fraunhofer IIS (http://www.iis.frauhofer.de/amm/). DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Unit of measure for the speed of data transmission Bits per second, the actual data rate BVIP Bosch Video over IP unit CompactFlash; interface standard, for digital storage media amongst other things. Used in computers in the form of CF cards, digital cameras and Personal Digital Assistants (PDA).
Page 116
It is controlled by a network operating system and uses a transfer protocol. Logical Unit Number; logical drive in iSCSI storage systems Media Access Control DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 117
Real-Time Streaming Protocol; network protocol for controlling the continuous transmission of audiovisual data (streams) or software over IP-based networks SD card Secure Digital Memory Card; digital memory card that works on the flash principle Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 118
User Datagram Protocol Uniform Resource Locator Unshielded Twisted Pair See Wide Area Network Wide Area Network A long distance link used to extend or connect remotely located local area networks DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Livepage 38 Device ID 33 Low Voltage Directive 6 Device name 27 DHCP server 29 Display stamping 36 Main functions 12 Dome camera 20 Maintenance 8 DSCP 83 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 121
Unit reset 104 Unit time 28 URL 23 User name 28 Value 43 Ventilation 17 Video content analysis 63 Video input 41 Video sensor 63 VRM 50 Watermarking 37 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V5.51 | 2012.03...
Page 122
122 en | Index VideoJet XF E DOC | V5.51 | 2012.03 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...