Processor Load; Network Connections; Terminal Block - Bosch VJD-3000 Installation Manual

Videojet decoder 3000
Hide thumbs Also See for VJD-3000:
Table of Contents

Advertisement

VIDEOJET decoder 3000
7.4

Processor load

If the unit is accessed via the Web browser, you will see the processor load indicator bar in
the top right of the window next to the information icon
You can obtain additional information to help you when troubleshooting or fine tuning the
unit. The values indicate the proportions of the individual functions on the coder load, shown
as percentages.
4
7.5

Network connections

You can display information about the network connection. To do this, move the cursor over
Link
UL
DL
7.6

Terminal block

The terminal block has several contacts for:
Pin assignment serial interface
Options for using the serial interface include transferring transparent data, controlling
connected units or operating the unit with a terminal program.
The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. The
mode used depends on the current configuration.
The pin assignment of the serial interface depends on the interface mode used:
Contact
CTS
TXD
RTS
RXD
GND
Bosch Sicherheitssysteme GmbH
Move the cursor over the graphic indicator. Some additional numerical values are also
displayed.
.
Ethernet link type
Uplink, speed of the outgoing data traffic
Downlink, speed of the incoming data traffic
Serial data transmission
4 alarm inputs
1 relay output
RS-232 mode
TxD (transmit data)
RxD (receive data)
GND (ground)
RS-422 mode
RxD- (receive data minus)
TxD- (transmit data minus)
TxD+ (transmit data plus)
RxD+ (receive data plus)
Installation Manual
Troubleshooting | en
.
RS-485 mode
Data-
Data+
2013.08 | V3 | F.01U.281.923
25

Advertisement

Table of Contents
loading

Table of Contents