Malfunctions With Iscsi Connections; Leds; Processor Load - Bosch VJT-X20XF-E Installation And Operating Manual

Videojet xf e series
Table of Contents

Advertisement

108 en | Appendix
Malfunction
Web browser contains
empty fields.
The CONNECT LED
flashes red.
8.3

Malfunctions with iSCSI connections

Malfunction
After connecting to the
iSCSI target, no LUNs are
displayed.
After connecting to the
iSCSI target, "LUN FAIL"
appears below a node.
LUN mapping is not
possible.
8.4

LEDs

The VideoJet XF E network video server has LEDs on its front and rear panels that show the
operating status and can give indications of possible malfunctions:
CONNECT LED
Does not light up:
Lights up green:
Lights up red:
Flashes green:
Flashes red:
LINK LED
Lights up green:
REC LED
Flashes orange:
8.5

Processor load

If the VideoJet XF E is accessed via the Web browser, you will see the processor load
indicator in the top left of the window next to the manufacturer's logo.
You can obtain additional information to help you when troubleshooting or fine tuning the
unit. The values indicate the proportions of the individual functions on the encoder load,
shown as percentages.
DOC | V5.51 | 2012.03
Possible causes
Active proxy server in network.
Firmware upload failed.
Possible causes
Incorrect LUN mapping during
iSCSI system configuration.
The LUN list could not be read,
as it was assigned to the wrong
network interface.
Some iSCSI systems do not
support the use of an initiator
extension.
VideoJet XF E is switched off.
VideoJet XF E is switched on.
Startup in progress.
Data packet transmission via network.
VideoJet XF E is faulty, for example following failed
firmware upload.
Network connection established.
Recording in progress.
Installation and Operating Manual
VideoJet XF E
Recommended solution
Create a rule in the local
computer's proxy settings to
exclude local IP addresses.
Repeat firmware upload.
Recommended solution
Check the iSCSI system
configuration and reconnect.
Check the iSCSI system
configuration and reconnect.
Delete the initiator extension on
the Identification configuration
page.
Bosch Sicherheitssysteme GmbH