Processor Load; Network Connection; Terminal Block - Bosch VIDEOJET multi 4000 Installation Manual

Table of Contents

Advertisement

VIDEOJET multi 4000
STATUS LED
Lights up:
Flashes:
CONNECT LED
Lights up:
Flashes:
RJ45 socket LEDs
Left LED flashes (as ACTIVITY
LED):
Right LED lights up (as LINK
LED):
7.5

Processor load

If the unit is accessed via the Web browser, you will see the processor load indicator bar in
the top right of the window next to the information icon
You can obtain additional information to help you when troubleshooting or fine tuning the
unit. The values indicate the proportions of the individual functions on the coder load, shown
as percentages.
4
7.6

Network connection

You can display information about the network connection. To do this, move the cursor over
Link
UL
DL
7.7

Terminal block

The terminal block has several contacts for:
Pin assignment serial interface
Options for using the serial interface include transferring transparent data, controlling
connected units or operating the unit with a terminal program.
Bosch Sicherheitssysteme GmbH
Move the cursor over the graphic indicator. Some additional numerical values are also
displayed.
.
Ethernet link type
Uplink, speed of the outgoing data traffic
Downlink, speed of the incoming data traffic
Serial data transmission
4 alarm inputs
1 relay output
Startup in progress.
The unit is faulty, for example following failed firmware
upload.
The unit is switched on and startup completed.
Video connection active.
Traffic on the network.
Network connection established.
Installation Manual
Troubleshooting | en
.
2014.02 | V1 | F.01U.298.750