Spectrum XF Maintenance Manual
7. In Manual Feed mode, simultaneously feed a stack of two, clean control sheets in
landscape orientation. The control sheets feed into the transport and remain there;
they are not ejected from the transport into the exit tray.
8. Once the control sheets are fed into the transport, the control panel LCD displays the
following messages/menus:
The Calibration in Progress menu contains a counter that displays the amount of time
the calibration is taking to complete
Note
The amount of time the calibration process takes to complete changes
depending on the model of scanner.
•
8140 = approximately 7 minutes
•
8120 = approximately 5 minutes
•
8090 = approximately 3.5 minutes
9. If the back camera is being calibrated instead of the front camera, the message on
the display will be changed accordingly to reflect this.
10. After the calibration process completes, the control sheets are ejected from the
scanner and the control panel LCD displays the following message:
11. The expected or normal result is that the calibration will pass. When it passes, press
the UP ARROW key to return to the Camera Calibration menu.
12. Press the CLEAR key to return to the Home menu, reset the initial scanner feed
mode (refer to the Spectrum XF Operator manual for instructions), and resume
scanning.
13. In the event of an error during calibration, the menu being displayed on the control
panel indicates which camera failed along with a numeric error code. Make sure the
control sheets are clean and perform the calibration again. If the control sheets show
dark marks after calibration, clean the transport area (refer to section
the Transport
Area) and retry. If calibration fails after three attempts, contact Böwe
Bell + Howell Technical Support. Refer to the
manual for details.
12 of 27
Calibration in progress
3:07
Figure 1.19: Calibration in Progress Menu
Saving front cal data...
DO NOT TURN OFF POWER!
Figure 1.20: Saving Front Cal Data Menu
Calibration Complete
DO NOT TURN OFF POWER!
Figure 1.21: Calibration Complete Message
CANCEL
Contact Information page
1.4.5 Cleaning
in this
S006504 Rev D