Software Download; Cleaning The Skimmer Rollers; Figure 1.22: Download New Software Menu - Bell and Howell Spectrum XF Maintenance Manual

Scanner
Table of Contents

Advertisement

Note
For a list of possible of camera calibration errors and how to troubleshoot
them, please refer to the Spectrum XF Operator manual.
The control panel contains a Software Download menu, which is used to prepare the
scanner to receive new control firmware. The new control firmware is downloaded using
special software for the host PC and a standard serial cable. In the unlikely event that
you must download new control firmware, Böwe Bell + Howell Technical Support will
contact you with instructions.
Note
If the Download New Software menu is started by mistake and no actual
download has begun, it is safe to cycle scanner power (shut down the host PC
first; then power the scanner off and then back on). The scanner will reset
itself and power up normally.
As the skimmer rollers become dirty, they may begin to slip on the paper or cause
multifeeds. To prevent feeding problems, clean the skimmer rollers once a day or as
needed.
Note
Different documents types and the condition of the documents being scanned
may require more frequent cleanings.
To clean the skimmer rollers, follow the procedure below:
1. Remove all documents from the ADF and exit tray.
2. Press the CLEAR key to return to the Home menu.
3. Press the CLEANING MENU key on the control panel.
4. Press the F1 key [START] to start the transport.
S006504 Rev D
Download new software?
Press F1 to confirm

Figure 1.22: Download New Software Menu

1.4.5
1 Operator Maintenance
1.4.4

Software Download

Cleaning the Skimmer Rollers

13 of 27

Advertisement

Table of Contents
loading