Table F-4: acBoardEvResettingBoard Alarm Trap
acBoardEvResettingBoard
1.3.6.1.4.1.5003.9.10.1.21.2.0.5
critical
equipmentAlarm
outOfService (71)
User resetting board
When a soft reset is triggered via the Web interface or SNMP.
Critical
After raise
Status stays critical until reboot. A clear trap is not sent.
A network administrator has taken action to reset the device. No corrective action
is required.
Table F-5: acFeatureKeyError Alarm Trap
acFeatureKeyError
1.3.6.1.4.1.5003.9.10.1.21.2.0.6
Critical
processingErrorAlarm
configurationOrCustomizationError (7)
Feature key error
Support for this alarm is pending
Table F-6: acBoardCallResourcesAlarm Alarm Trap
acBoardCallResourcesAlarm
1.3.6.1.4.1.5003.9.10.1.21.2.0.8
Major
processingErrorAlarm
softwareError (46)
Call resources alarm
Number of free channels exceeds the predefined RAI high threshold.
Major
To enable this alarm the RAI mechanism must be activated (EnableRAI = 1).
Number of free channels falls below the predefined RAI low threshold.
Cleared
413
F. SNMP Traps
December 2006