H.323 User's Manual
5.9.3

Resetting the Mediant 1000

The 'Maintenance Actions' screen enables you to remotely reset the gateway. Before you
reset the gateway, you can choose the following options:
Save the gateway's current configuration to the flash memory (non-volatile).
Perform a graceful shutdown. Reset starts only after a user-defined time expires or no
more active traffic exists (the earliest thereof).
To reset the gateway, take these 6 steps:
Open the 'Maintenance Actions' screen (Maintenance menu); the 'Maintenance
1.
Actions' screen is displayed.
Under the RESET group, from the 'Burn To FLASH' drop-down list, select one of the
2.
following options:
'Yes': The gateway's current configuration is burned (i.e., saved) to the flash
memory prior to reset (default).
'No': Resets the device without burning (i.e., saving) the current configuration to
flash (discards all unsaved modifications to the configuration).
Under the RESET group, from the 'Graceful Option' drop-down list, select one of the
4.
following options:
'Yes': Reset starts only after the user-defined time in the Shutdown Timeout field
(refer to Step 5) expires or no more active traffic exists (the earliest thereof). In
addition, no new traffic is accepted.
'No': Reset starts regardless of traffic and any existing traffic is terminated at
once.
Version 5.0

Figure 5-70: Maintenance Actions Screen