Blanking Reset; Blanking Enable, Write; Blanking Enable, Read - Barco RLM series User Manual

Rs232 commands
Table of Contents

Advertisement

2. Basic Commands

2.41.1 Blanking Reset

Description
Allows the reset of the blanking values.
Command
Command [0]
Data
byTypeBlanking : 1 byte describing the type of blanking.
Data [0] = 0 : blanking done and saved in the image file
Data [0] = 1: blanking done on the display
The maximum number of pixels which can be blanked depends on the native resolution of the panels

2.41.2 Blanking enable, Write

Description
Enables the blanking.
Command
Command [0]
Command [1]
Data
Data[0] = byTypeBlanking
Data[0] = 0 : blanking on image file
Data[0] = 1: blanking on display
Data[1] = unsigned byte
Data[1] = 0 : disable
Data[1] = 1 : enable

2.41.3 Blanking enable, Read

Description
Reads whether the blanking is enabled.
Command
Command [0]
Command [1]
Sent Data
byTypeBlanking : one byte describing the type of blanking
Data [0] = 0 : blanking on image file (saved in image file)
Data [0] = 1 : blanking on display
Returned Data
Data[0] = byTypeBlanking
Data[0] = 0 : blanking on image file
Data[0] = 1: blanking on display
Data[1] = unsigned byte
80
\x17
\x20
\x56
\x21
\x56
R5976884 RLM SERIES 04/04/2006