Logging Facility‐Type specifies the syslog facility to use for messages, (16 to 23) local 0 to 
local 7.
LoggingClear button clears the event log.
The system allows you to limit the messages that are logged by specifying a minimum severity 
level. Table
4‐4 lists the error message levels from the most severe (Alert) to least severe (Debug). 
The message levels that are logged include the specified minimum level up to the Alert level.
Table 4-4 Logging Level Descriptions
Error Level Description
Emergency
Immediate action needed
Alerts
Immediate action needed
Critical
Critical conditions (e.g., memory allocation, or free memory error - resource exhausted)
Error
Error conditions (e.g., invalid input, default used)
Warning
Warning conditions (e.g., return false, unexpected return)
Notice
Normal but significant condition, such as cold start
Informational
Informational messages only
Debug
Debugging messages
Note: The access point error log can be viewed using the Event Logs window in the Status section
(refer to
"Using Web Management to View Event
displays the last 128 messages logged in chronological order, from the newest to the oldest. Log
messages are erased when the device is rebooted.
Logs" on page 4-90).The Event Logs window