FDB

Static FDB Settings

Unicast Static FDB Settings
Users can set up static unicast forwarding on the Switch.
To view the following window, click L2 Features > FDB > Static FDB Settings > Unicast Static FDB Settings, as
shown below:
The fields that can be configured are described below:
Parameter
VLAN Name
VLAN List
MAC Address
Port/Drop
Description
Select the unit you want to configure. (EI and SI Mode Only)
A consecutive group of ports may be configured starting with the selected port.
Active - Active LACP ports are capable of processing and sending LACP control frames.
This allows LACP compliant devices to negotiate the aggregated link so the group may
be changed dynamically as needs require. In order to utilize the ability to change an
aggregated port group, that is, to add or subtract ports from the group, at least one of the
participating devices must designate LACP ports as active. Both devices must support
LACP.
Passive - LACP ports that are designated as passive cannot initially send LACP control
frames. In order to allow the linked port group to negotiate adjustments and make
changes dynamically, one end of the connection must have "active" LACP ports (see
above).
Figure 4-43 Unicast Static FDB Settings window
Description
Click the radio button and enter the VLAN name of the VLAN on which the associated
unicast MAC address resides.
Click the radio button and enter a list of VLAN on which the associated unicast MAC
address resides.
The MAC address to which packets will be statically forwarded. This must be a unicast
MAC address.
Allows the selection of the port number on which the MAC address entered above resides
This option could also drop the MAC address from the unicast static FDB. When selecting
Port, enter the port number in the field. The format can be "unit ID:port number" (e.g. 1:5)
or "port number" (e.g. 5). When only entering port number, the default unit ID is 1.