4-16 Configuring Your Server
Option
Thermal Sensor
BMC IRQ
Post Error Pause
AC-LINK
Power ON Delay
Time (Sec)
Platform Event
Filtering
IMPORTANT:
Power Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
System status before AC power off
Operating
Aborting (DC power being off also)
Forced shutdown
* Press the power switch continuously for four seconds or longer. This forcibly turns off the power.
Parameter
Description
Disabled
Specify whether to enable or disable the
thermal sensor monitoring function. If a
[Enabled]
thermal error is detected with this item
being set to "Enabled", the system stops
at the end of POST.
Determines routing of the BMC
Disabled
interrupt.
[IRQ 11]
Disabled
Specify whether to stop the POST once
at the end of POST if an error occurs
[Enabled]
during the POST.
Stay Off
Specify the state of power when the AC
power to the server is turn off once and
[Last State]
then on.
Power On
[0] - 255
Specify the power on delay time within
the range between 0 and 255 seconds.
The time specified is valid when "Power
On" or "Last State" is specified for AC
LINK.
Disabled
Specify whether to enable or disable the
platform event filtering (PEF) feature.
[Enabled]
To power on the server from the UPS (Uninterruptible
Setting of AC LINK
Stay Off
Last State
Off
On
Off
Off
Off
Off
Your Setting
[
]: Factory-set
Power On
On
On
On