MILLIVOLT BOARD INSTALLATION

MILLIVOLT BOARD INSTALLATION
WARNING: DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER THE MILLIVOLT BOARD) IN PLACE.
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
1.
Place millivolt board in firebox, aligning holes in the millivolt
board with mounting studs in the firebox bottom. MAKE SURE
SEALING GASKET IS IN PLACE ON FIREBOX BOTTOM!
Secure millivolt board to firebox bottom with (8) 1/4" nuts.
CAUTION: BEFORE SECURING MILLIVOLT BOARD INTO
PLACE, CHECK THAT ALL WIRES UNDERNEATH ARE
CLEAR AND UNOBSTRUCTED. DO NOT ALLOW ANY
WIRES OR FLEXLINES TO TOUCH FAN TERMINALS.
2.
Install burner assembly, making sure burner tube is positioned
over burner orifice, and alignment slots are placed over mounting
studs on millivolt board. Secure with 1/4" nuts.
3.
Install pilot shield around pilot assembly.
4.
Connect gas line to manual shut-off valve.
5.
Connect any wall switch, remote control or thermostat wires to
terminals on valve marked „TH‟ / „THTP‟.
6.
Install log set. Page 24.
7.
Install glass frame assembly. Page 9.
8.
Verify proper log placement, operation of insert and any electrical
components.
CAUTION: CHECK ALL CONNECTIONS FOR LEAKS, WHETHER FIELD OR FACTORY MADE.