KOZY HEAT #815-CL CO-LINEAR VENT SYSTEM
NOTE: The co-linear pipe included with this vent system is designed to extend up to 25 ft. (7.62 m).
If additional length is required, Part #510 is available to extend the venting to a maximum of 40 ft (12.19 m).
A. Carefully extend the 3" combustion intake and 4" exhaust pipes (and extension kit if used) to equal the total chimney length required.
NOTE: If using „stub‟ method for the combustion air pipe, extending it is not necessary. Determine length
needed from the air duct on insert (4 ft. (1.22 m) minimum) to above the damper opening in the exist-
ing chimney. Remove excess combustion air pipe from end without a collar. Continue with Step B. #2
below.
B.
If using „Full Connection‟ method:
1. Slide 3" intake pipe (end without collar) over collar on termination cap. Secure with 3 self-tapping screws (provided).
2. Place a bead of sealant around inner edge of 4" exhaust pipe (end without collar) and slide onto corresponding collar on termination
cap. Secure with 3 self-tapping screws (provided). Apply additional sealant around joint to ensure a seal.
C.
If an extension kit is being used, it must be connected as follows:
Exhaust extension: Apply a liberal bead of sealant around exhaust adaptor (male) extension pipe and slide into female connector on end of
4" exhaust pipe already attached to the chimney termination plates. Secure with 3 self-tapping screws, (provided). To
ensure an air-tight seal, additional sealant should be applied at the point of connection.
Combustion intake extension: Apply a liberal bead of sealant (provided) around male end of extension kit and slide into female end of 3"
VENTING INSTALLATION
combustion intake pipe attached to the chimney termination plates. Secure with 3 self-tapping screws
(provided). To ensure an air-tight seal, additional sealant should be applied at the point of connection.