9Xl-Msp Masonry Side Panel Installation (Optional); Restrictor - kozy heat 911XL Installation And Operation Manual

Direct vent insert
Hide thumbs Also See for 911XL:
Table of Contents

Advertisement

#9XL-MSP MASONRY SIDE PANEL INSTALLATION (OPTIONAL)

IMPORTANT: For use when the insert is installed in an existing masonry opening.
This kit must be attached to the air duct (manifold) prior to vent system connection.
This kit includes: (1)
Right side panel
(1)
Left side panel
(12) sheet metal screws
NOTE: If the air duct and masonry side panels are not placed „outside‟ the flanges at insert bottom, a rattling noise may occur
when the fan is in operation.
1.
If air duct on insert is not positioned outside flange at bottom, remove
and reposition.
2.
Position side panels outside flanges on insert bottom, align (2) holes in
top and (2) holes in back of masonry side panels with corresponding
holes in air duct. Secure with screws.
This installation will be continued at a later point.

RESTRICTOR

Each installation is unique and affected by various factors including venting configuration, altitude and climate. Therefore, after fireplace insert
installation is complete, a restrictor may be required or may need to be removed or modified.
Page 31 has information on restrictor recommendations depending on burner flame appearance and instructions on installation after venting is
completed.
RESTRICTOR INSTALLATION
IMPORTANT: DO NOT INSTALL IF THE VENTING CONFIGURATION
IS AT THE MINIMUM REQUIREMENTS!
Large Restrictor
INSTALLATION
Remove tab (s) to create
small restrictor
Bend tabs to approx. 80 degree
angles to create tension to hold
itself in place when installed.
PAGE 14
Masonry side panels and air duct
must be positioned outside
flange at bottom of insert
Slide restrictor into exhaust pipe with tabs
pointing toward you.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

911xl-radJackson xlJackson xl 911xl

Table of Contents