FAN DIRECT WIRE INSTALLATION

#911XL
#911XL-RAD OPTIONAL FAN KIT #911-028
DIRECT WIRE CONNECTION MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN.
911XL:This fireplace insert comes complete with a fan and thermostatic control switch already installed. A speed control, receptacle, and
8 ft. (2.44 m) fan cord have been installed, wired and mounted in a removable electrical box panel on the right side of the fireplace. If wir-
ing to the pre-installed electrical box is desired, the wiring should be run prior to permanently setting the insert in place and connecting the
vent system.
911XL-RAD: A speed control, receptacle, and 8 ft. (2.44 m) fan cord have been installed, wired and mounted in an electrical box panel
included with fan kit. If hardwiring to the electrical box is desired, the wiring should be run prior to permanently setting the insert in place
and connecting the vent system.
NOTE: If this fireplace insert is being installed in the minimum opening dimensions,
the wiring may need to be completed after the fireplace insert is set in place.
WARNING: This appliance is equipped with a three-prong (grounding) plug for
protection against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug. Do not allow any excess fan cord to touch the fireplace.
NOTE: Code approved line voltage wiring 14 gauge or better must be used when
wiring this assembly. Refer to your local electrical codes for specific requirements in
your area.
DIRECT WIRE INSTALLATION:
NOTE: The cord must be removed and wiring disassembled.
Insert 110V-120V wiring (with ground) through the romex connector and
wire to speed control / receptacle assembly, matching black, white & green
(ground) wires to the corresponding wires on the speed control / receptacle
assembly.
110V-120V
60Hz
DIRECT WIRE INSTALLATION
1.
911XL: Remove nut securing speed control / receptacle assembly from right side of insert floor.
2.
911XL / 911XL-RAD: Remove (2) screws securing speed control / receptacle to expose wiring.
3.
Remove existing cord and insert 110V-120V wiring (with ground) through romex connector, wiring to speed control / receptacle
assembly, matching black (hot), white (neutral), and green (ground) wire to the corresponding wires on speed control / receptacle
assembly. NOTE: The (3) wire nuts obtained when removing existing cord may be used for this purpose.
4.
Secure speed control / receptacle assembly into the electrical box with (2) screws provided.
5.
Re-attach electrical box to insert floor with nut removed in step 1.
NOTE: A mounting stud has been provided on the right side of
fireplace to reposition the speed control / receptacle assembly if desired.
Refer to page 18 for instructions on completing fan wiring after insert has been installed.
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Codes, CSA C22.1
Electrical Box
Speed Control /
Receptacle Assembly
PAGE 10
Temperature Switch:
Magnetically attaches to bottom of
firebox.