Installation; Approved Venting; Air Duct Removal; Millivolt Board Removal - kozy heat 911XL Installation And Operation Manual

Direct vent insert
Hide thumbs Also See for 911XL:
Table of Contents

Advertisement

IMPORTANT: ALL STEPS AS OUTLINED IN „PREPARE THE EXISTING FIREPLACE‟ MUST BE COMPLETED BEFORE
CONTINUING WITH THIS INSTALLATION.

APPROVED VENTING

Kozy Heat #815-CL Co-Linear Vent System. Follow instructions on following pages.
Selkirk, ICC, American Metals, Security
Follow instructions included from vent pipe manufacturer as well as the venting requirements as outlined in this installation manual.

AIR DUCT REMOVAL

Remove air duct by lifting up and off top of insert. Follow instructions
below and on following pages for vent system attachment to air duct.
IMPORTANT: To properly install the air chute, it is necessary to remove the millivolt board/burner assembly. For your convenience,
we have installed only 2 of the 8 nuts required to properly secure the millivolt board to the insert firebox floor. The remaining nuts are
included in the components packet, and will be used at a later point to re-install the millivolt board .

MILLIVOLT BOARD REMOVAL

1.
Remove and save nuts securing burner cover assembly. Remove burner assembly.
2.
Remove and save 2 nuts securing millivolt board. Remove millivolt board from fireplace, being careful not to damage gasket located
.
under millivolt board
NOTE: If millivolt board removal for servicing or maintenance requirements is needed after installation of this fireplace insert has
been finalized, please refer to page 20 for complete instructions.

INSTALLATION

PAGE 13
Air Duct