MILLIVOLT BOARD REMOVAL
CAUTION: If the burner and/or pilot have been burning, use the appropriate protection to avoid burns or damage to personal property before
removing any components.
1.
Turn gas control knob to the „OFF‟ position.
2.
Shut off gas supply at the manual shut-off valve.
3.
Disconnect gas line flex tube from the manual shut-off valve.
4.
Disconnect any wall switch, remote control, or thermostat wires
from „TH‟ / „THTP‟ terminals on the gas valve.
5.
Remove glass assembly. Page 9.
NOTE: It is not necessary to remove the shroud or full
door shroud to remove millivolt board.
6.
Remove logs.
7.
Remove nuts securing burner assembly. Remove burner assem-
bly from firebox.
8.
Remove pilot shield.
9.
Remove (8) nuts securing millivolt board. Lift board up and out
of firebox.
PAGE 20
(after installation)
Pilot Shield