Finalizing The Installation; Flame Appearance; Venturi Adjustment - kozy heat 911XL Installation And Operation Manual

Direct vent insert
Hide thumbs Also See for 911XL:
Table of Contents

Advertisement

FLAME APPEARANCE:

Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has
been factory set, adjustments may be necessary for optimal performance and visual aesthetics.
When fireplace is first lit, the flames will be blue. The flames will gradually turn yellowish-orange during the first 15 minutes of opera-
tion. If the flames remain blue or the flames become dark orange with evidence of sooting (black tips), the burner tube venturi may need
to be adjusted.
WARNING: BURNER TUBE ADJUSTABLE VENTURI POSITIONING SHOULD ONLY BE PERFORMED BY A
QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.
WARNING: TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY, ALLOW FIREPLACE AMPLE TIME TO
COOL BEFORE MAKING ANY ADJUSTMENTS.
FACTORY SET BURNER TUBE VENTURI SETTINGS
(ADJUST AS NECESSARY FOR YOUR INSTALLATION)
NATURAL GAS
1/4" (6 mm) OPEN
VENTURI POSITION
Closed too far
Open too far
NOTE: IF SOOT IS PRESENT, CHECK LOG POSITIONING BEFORE ADJUSTING BURNER VENTURI. LOGS
MUST NOT BLOCK BURNER PORTS.
IMPORTANT: SLIGHT ADJUSTMENTS TO THE BURNER VENTURI OPENING CREATE DRAMATIC RESULTS.
ADJUST AT SLIGHT INCREMENTS UNTIL DESIRED LOOK IS ACHIEVED. ALWAYS BURN FIREPLACE FOR
AT LEAST 15 MINUTES AND ALLOW TIME TO COOL BEFORE MAKING ANY FURTHER ADJUSTMENTS.
TO ADJUST VENTURI:
1.
Remove glass frame assembly. Refer to page 9.
2.
Remove log set.
3.
Remove burner assembly. Refer to page 20.
4.
Loosen screw on burner venturi and adjust as necessary.
Tighten screw.
5.
Reinstall all components previously removed.
6.
Light fireplace and wait 15 minutes before determining if
any further adjustments are needed.

FINALIZING THE INSTALLATION

LP (PROPANE) GAS
1/2" (13 mm) OPEN
BURNER TUBE VENTURI ADJUSTMENT GUIDELINES
FLAME COLOR
Dark orange flame with black tips
Blue flames

VENTURI ADJUSTMENT

Open venturi setting slightly
Close venturi setting slightly
BURNER VENTURI
PAGE 30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

911xl-radJackson xlJackson xl 911xl

Table of Contents