Removing and Replacing the System Control Board

Replacing the System
Control Board
Quantum Scalar i40 and Scalar i80 User's Guide
Chapter 9: Installing, Removing, and Replacing Components
The power supply only goes in one way, and should slide in easily. If
you cannot slide it in, you may be trying to install it upside down.
7 Tighten the two thumbscrews finger tight.
8 Connect the power cord to the power supply.
9 Make sure the power cord is plugged in to a grounded, AC outlet.
The power supply LED should turn green immediately to indicate
the library is turned on.
If the power supply LED is red, the power supply is not working.
Contact Quantum Support.
These instructions explain how to remove a system control board (SCB)
and replace it with a new one.
The SCB contains library firmware, tape drive firmware, all configurable
settings, license keys, and SKM TLS certificates. After you replace the
SCB, you must either restore a previously saved configuration, or
reinstall the license keys and manually reconfigure the settings.
Note: When you replace the SCB you will permanently lose all data
previously collected for logs and reports.
The process steps are:
1

Replacing the System Control Board

2
Installing Library Firmware
3
Restoring the Library Configuration
Library
Caution: You must completely remove power from the library before
removing and replacing the system control board.
Removing and Replacing the System Control Board
or
Manually Reconfiguring the
279