5.22

Alarm Configuration

Alarm Configuration
Function name:
Events Configuration
Function description:
The Trap Events Configuration function is used to enable the switch to send out trap information
while pre-defined trap events occur. The switch provides 24 different trap events. The trap
information can be sent out in three ways, including email, mobile phone SMS (short message
system) and trap. The message will be sent if you check ( ) the trap event individually on the web
page shown below.
Parameter description:
Trap: Cold Start, Warm Start, Link Down, Link Up, Authentication Failure, User login, User logout
STP: STP Topology Changed, STP Disabled, STP Enabled
LACP: LACP Disabled, LACP Enabled, LACP Member Added, LACP Port Failure
GVRP: GVRP Disabled, GVRP Enabled
VLAN:
VLAN Disabled, Port-based VLAN Enabled, Tag-based VLAN, Enabled, Metro-mode VLAN
Enabled, Double-tag VLAN Enabled
Module Swap: Module Inserted, Module Removed, Dual Media Swapped
Waters Network Systems
Events Configuration
Email/SMS Configuration
Figure 5.59 – Trap Events Configuration