Logic Command/Status Words; Powerflex 4 And Powerflex 40 Drives - Allen-Bradley 22-COMM-E FRN 1.xxx User Manual

Ethernet/ip adapter
Table of Contents

Advertisement

Logic Command/Status Words

Appendix D provides the definitions of the Logic Command/Logic
Status words that are used for some products that can be connected to the
EtherNet/IP adapter. If you do not see the Logic Command/Logic Status
for the product that you are using, refer to your product's documentation.

PowerFlex 4 and PowerFlex 40 Drives

Logic Command Word
Logic Bits
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Command
x x
x x x
x
(1)
A 0 = Not Stop condition (logic 0) must first be present before a 1 = Start condition will start the drive.
x
x
x x
x
x
x x
x Stop
0 = Not Stop
1 = Stop
(1)
x
Start
0 = Not Start
1 = Start
Jog
0 = Not Jog
1 = Jog
Clear Faults
0 = Not Clear Faults
1 = Clear Faults
Direction
01 = Forward Command
10 = Reverse Command
11 = No Command
Not used
Not used
Accel Rate
00 = No Command
01 = Accel Rate 1 Command
10 = Accel Rate 2 Command
11 = Hold Accel Rate
Decel Rate
00 = No Command
01 = Decel Rate 1 Command
10 = Decel Rate 2 Command
11 = Hold Decel Rate
Reference
000 = No Command
Select
001 = Freq Source = Select
010 = Freq Source = Int. Freq
011 = Freq Source = Comm
100 = Preset Freq 0
101 = Preset Freq 1
110 = Preset Freq 2
111 = Preset Freq 3
Not used
Appendix
Description
00 = No Command
D