HP ProCurve 6120G/XG Configuration Manual page 558

Procurve series 6120 blade switches management and configuration guide
Hide thumbs Also See for ProCurve 6120G/XG:
Table of Contents

Advertisement

Troubleshooting
Debug/Syslog Operation
2. To use a CLI session on a destination device for debug messaging:
3. Enable the types of debug messages to be sent to configured Syslog
4. If necessary, enable a subset of Event Log messages to be sent to config­
ProCurve(config)# logging severity < debug | major | error | warning | info >
ProCurve(config)# logging system-module < system-module >
5. If you configure system-module and/or severity-level values to filter Event
ProCurve(config)# no logging severity < debug | major | error | warning | info>
ProCurve(config)# no logging system-module < system-module >
C-40
b. Re-enter the logging command in Step "a" to configure additional
Syslog servers. You can configure up to a total of six servers. (When
multiple server IP addresses are configured, the switch sends the
debug message types that you configure in Step 3 to all IP addresses.)
a. Set up a serial, Telnet, or SSH connection to access the switch's CLI.
b. Enter the debug destination session command at the manager level.
servers and/or the current session device by entering the debug < debug-
type > command:
ProCurve# debug <all|arp-protect|event|ip
[bgp|forwarding|packet|rip|routemap]|ipv6|lldp>
Repeat this step if necessary to enable multiple debug message types.
By default, Event Log messages are sent to configured debug destination
devices. To block Event Log messages from being sent, enter the no debug
event command.
ured Syslog servers by specifying a severity level and/or system module
using the following commands
To display a list of valid values for each command, enter logging severity
or logging system-module followed by ? or pressing the Tab key.
The severity levels in order from the highest to lowest severity are: major,
error, warning, info, debug. For a list of valid values for the logging system-
module <system-module > command, refer to Table C-1 on page C-25.
Log messages, when you finish troubleshooting, you may want to reset
these values to their default settings so that the switch sends all Event Log
messages to configured debug destinations (Syslog servers and/or CLI
session).
To remove a configured setting and restore the default values that send
all Event Log messages, enter one or both of the following commands: