Intermec MobileLAN access WA21 System Manual page 241

Mobile lan access series
Hide thumbs Also See for MobileLAN access WA21:
Table of Contents

Advertisement

Purpose: Sets the internal variable terminate to a specified value. Use terminate to
Syntax:
Purpose: Sets the setactivepointers command to change inactive segments to active
Syntax:
Example: To change the inactive boot and data segments to active at the next
Purpose: Sets the nextpoweruptime command to set the internal variable
MobileLAN access System Manual
sdvars set terminate
stop a countdown process in the access point. If either starttime or
nextpoweruptime is counting down, setting this variable stops the timer
and halts the countdown process.
Note: You should use caution when using this command. If the script file
is being downloaded or executed, setting this variable interrupts the
processing and can leave the access point in an undetermined state that
may require user intervention.
sdvars set terminate
sdvars set setactivepointers
segments the next time the access point is rebooted. This command is
usually used with the nextpoweruptime command.
sdvars set setactivepointers none/boot/data/both
where:
none
does not change the active segments. The default is
Also, when the reboot is completed, the access point resets
this value to
boot
changes the inactive boot segment to the active boot segment.
data
changes the inactive data segment to the active data segment.
both
changes both the boot and data inactive segments to the
active segments.
reboot, enter:
sdvars set setactivepointers both
sdvars set nextpoweruptime
nextpoweruptime to a countdown time so that when 0 is reached, the
access point will reboot. When the nextpoweruptime counter reaches 0,
the access point checks the value of the setactivepointers variable, takes the
appropriate action, and then reboots.
Note: If you need to terminate the reboot, you can do so by setting
nextpoweruptime to 0 if it has not already been reached by the
countdown. By resetting nextpoweruptime to 0, the timer is stopped so
the unit does not reboot.
Chapter 9 — Additional Access Point Features
.
none
none.