Environmental Specifications; System I/O Addresses - Gateway 7250R System Manual

Gateway server user manual
Hide thumbs Also See for 7250R:
Table of Contents

Advertisement

Environmental specifications

The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
Temperature, operating
Humidity, operating
Altitude
Voltage, AC input
Frequency
Certification

System I/O addresses

The following table shows the location in I/O space of all directly
I/O-accessible registers.
Address
0000h - 000Fh
0010h - 001Fh
0020h - 0021h
0022h - 0023h
0024h - 0025h
0026h - 0027h
0028h - 0029h
002Ah - 002Bh
002Ch - 002Dh
002Eh - 002Fh
0030h - 0031h
0032h - 0033h
0034h - 0035h
0036h - 0037h
0038h - 0039h
003Ah - 003Bh
003Ch - 003Dh
116
System Specifications
5° to 35° Celsius or
44° to 95° Fahrenheit.
20% to 80%
-200 feet to 10,000 feet
90 to 135 VAC, 180 to 255 VAC
47 to 63 Hz
FCC Class A, UL, CUL, CAN/CSA STD C22.2 No. 950,
CE Mark, VCCI Class A, CB scheme
Resource
DMA Controller 1
DMA Controller 1
Interrupt Controller 1
Interrupt Controller 1
Interrupt Controller 1
Interrupt Controller 1
Super I/O Index and Data Ports
Interrupt Controller 1
Interrupt Controller 1