PCI Expansion Slots
Power Supply
Certification
Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
Variable
Temperature
Nonoperating
Operating
Altitude
Humidity
Nonoperating
Shock
Operating
Packaged
130
Reference Data
Six full length, hot-pluggable PCI slots (four 64-bit, 33MHz and two 64-bit,
66MHz), and two half-length PCI slots (32-bit, 33MHz).
One to three, 375 watt power supplies.
FCC Class A, UL, CUL, CE Mark, VCCI, CB Scheme.
Requirements
Maximum rate of change = 10° C per hour
–40° to 70 °C (–38° to 158 °F)
10° to 35 °C (50° to 95 °F); derated 0.5 °C for every
1000 ft. (305 m), with a maximum rate of change of
10°C/Hour
10,000 ft. max
95% relative (noncondensing) @ 30° C (86° F)
2.0 g, 11 msec, 1/2 sine
Operational after 30-inch free fall (cosmetic damage
might occur)