Environmental Specifications - Gateway 960 User Manual

Hide thumbs Also See for 960:
Table of Contents

Advertisement

Environmental specifications

The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
Variable
Temperature
Altitude
Humidity
Shock
AC input power
Requirements
Maximum rate of change: 18°F (10°C) per hour
Nonoperating: -55° to 150°F (-48.3° to 65.5°C)
Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every
1,000 feet (305 meters)
10,000 feet (3,048 meters) maximum
Operating wet bulb: Not to exceed 91.4°F (33 °C) (with diskette drive
or hard drive)
Nonoperating: 95% relative (noncondensing) at 86° F (30° C)
Operating: 2.0 g, 11 msec, ½ sine
Packaged: Operational after 30-inch free fall (cosmetic damage might
occur)
100-127 V∼, 8.5 A, 50/60 Hz
200-240 V∼, 4.0 A, 50/60 Hz
www.gateway.com
123

Advertisement

Table of Contents
loading

Table of Contents