Setting Mid-Stop Limit; Resetting The Mrt - Genie GCL-J&H Installation Manual

Jackshaft/hoist standard duty commercial/industrial door operator
Table of Contents

Advertisement

Setting Mid-Stop Limit

The Operator includes a programmable Mid-Stop. This feature allows the operator
to stop at a user selectable point when opening. It is used when operating very tall doors
that only open to their full height occasionally. The Mid-Stop does not effect the operator
when closing. To operate door to full open position from mid-stop, press open button again.
NOTE: Setting of the MID-STOP should only be performed AFTER Travel
Limit and Max Run Timer settings have been made.
CAL
1) Press CAL/RUN
key to enter calibration mode.
RUN
2) Press the CLOSE
key to close the door to the down limit.
CLOSE
key until display reads "MID-STOP > CLR" Figure 16.
3) Press SCROLL
CROLL
NOTE: If the display reads MID-STOP > SET at this point, first clear the
MID-STOP as described below then repeat steps 1-3 and continue.
4) Press the OPEN
key to open the door to desired mid-stop height.
OPEN
keyuntil the display reads "MID-STOP > SET"
5) Press SET/CLEAR
SET
CLEAR
6) Press CAL/RUN
CAL
key to return to run mode.
RUN
To CLEAR the Limit
CAL
1) Press CAL/RUN
to enter calibration mode.
RUN
until display reads "MID-STOP > SET"
3) Press SCROLL
SCROLL
until the display reads "MID-STOP > CLR"
SET
5) Press SET/CLEAR
CLEAR
8) Press CAL/RUN
CAL
to return to run mode.
RUN

Resetting the MRT

(The Max Run Timer is set automatically once the unit is cycled between
Limits. The Max Run Timer prevents the unit from running continuously in the event of a problem.
The MRT's are set to the time required to run from one limit to the other, plus 5 seconds (nominal).
When the MRT is exceeded, the operator stops and will not respond to any command until it is reset
by pressing one of the Calibration keys or by cycling power to the unit.
TO RESET
CAL
1) Press CAL/RUN
to enter calibration mode.
RUN
2) Press SCROLL
(up or down) until display reads "MAX RUN TMR > SET." Figure 17.
SCROLL
3) Press SET/CLEAR
until display reads "MAX RUN TMR > CLR."
SET
CLEAR
4) Press CAL/RUN
to return to RUN mode.
CAL
RUN
5) Cycle the door between limits.
NOTE: The Max Run Timer must be reset each and every time the Travel Limits are adjusted.
GCL-J&H
Standard Duty Operator
www.geniecompany.com
MID-STOP CLR
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 16
CAUTION:
The MID-STOP feature must be turned off in
order to properly set the Max Run Timer.
MAX RUN TMR SET
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 17
0 -12
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
6.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents