Wall Control

WARNING:
Wall Control(s) must be located so that the door is within sight of
the user and is far enough from the door, or positioned such that
the user is prevented from coming in contact with the door while
operating the controls .
Attach the Warning placard adjacent to the Wall Control. Fig. 3A.
WARNING:
If momentary contact control is to be used, an external monitored reversing
device such as a photocell system or sensing edge switch must be used.
See pages 5.7-5.8 for installation of entrapment protection devices.
1) For a single 3 - button installation, make connections as
shown in Fig. 3.
2) For single button accessory controls, make connections as
shown in Fig. 4.
3) For a multiple 3 - button installations, make connections as
shown in Fig. 5.
NOTE: If an External STOP button is NOT being installed, a jumper wire
must be installed between the "STOP" AND "GND" terminals as shown
on page 5.3.
NOTE: Long Distance Relay Kit wiring is not required for long
distance control runs and should not be used
GCL-J&H
Standard Duty Operator
Figure 3A
Figure 4
CONTROL SIGNAL TERMINAL STRIP
GND
STOP
www.geniecompany.com
Figure 3
CONTROL SIGNAL TERMINAL STRIP
OPEN
CLOSE
STOP
NOTE:
JUMPER BETWEEN
STOP AND GND
TERMINALS MUST
BE REMOVED
Entrapment
Warning
Placard
11 735
CONTROL SIGNAL TERMINAL STRIP
ODC
1-BTN
OPEN
CLOSE
STB
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
OPEN/CLOSE
PULL SWITCH
3-BUTTON
GND
STATION
OPEN
CLOSE
STOP
Figure 5
STOP
GND
NOTE:
JUMPER BETWEEN
STOP AND GND
TERMINALS MUST
BE REMOVED
OPEN
OPEN
CLOSE
CLOSE
STOP
STOP
3-BUTTON
3-BUTTON
STATION
STATION
5.4
0 -12